Warning: Undefined array key "background_overlay_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/section.php on line 268

Warning: Undefined array key "background_overlay_hover_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/section.php on line 272

Warning: Undefined array key "background_overlay_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/column.php on line 166

Warning: Undefined array key "background_overlay_hover_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/column.php on line 167

Warning: Undefined array key "background_overlay_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/column.php on line 166

Warning: Undefined array key "background_overlay_hover_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/column.php on line 167

Warning: Undefined array key "background_overlay_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/column.php on line 166

Warning: Undefined array key "background_overlay_hover_background" in /home/bhgpojyj/sample1.bhgpower.co.za/wp-content/plugins/elementor-theme-core/inc/elementor/column.php on line 167

Durapower DP 3000M is a proudly South African company specialising in the design and manufacturing of standby power equipment.

This transformer based, true on-line, double conversion UPS ensures that the critical load is supplied with clean sine wave power from the inverter. Incorporating the latest IGBT technology in the power stages, and microprocessor technology in the control stages, protects the provision of safe, reliable power to the critical loads, regardless of severe disturbances on the incoming supply. A standard make before break maintenance bypass switch is provided, to enable maintenance isolation on the system. This allows the load to be switched directly onto the utility supply, without interruption of the load supply.

Durapower DP 3000M (10-60KVA) UPS

Durapower DP 3000M

Models

UOM

DP3010M DP3015M DP3020M DP3030M DP3040M DP3050M DP3060M

Nominal Power Rating at 0.8 pf

KVA 10 15 20 30 40 50

60

Output Parameters
Inverter Type

High frequency IGBT DSP controller

Output power

KW

8 12 16 24 32 40

48

Output Current at rated KVA

A

14 22 29 43 58 72

87

Output Voltage

VAC

380/400/415 (400V standard) 3PH 4W + Neutral
Output Voltage Regulation

%

+/- 1%
Output Voltage THD

%

<2% for linear loads, <5% for 3:1 Crest factor loads

Output Frequency

Hz

50

Output Frequency Regulation

%

50Hz +/- 0.02

Output Frequency Window Hz

48.5Hz-51.5Hz synch to mains

Output Voltage Dynamic Regulation

%

+/-5% (100% load step) Recovery to 2% within 20ms

Overload Capacity KVA

%FL

105% continuous/ 110% 10min / 125% 1min / 150% 25sec

Overload Capacity KW

%FL

110% continuous/ 150% 1min / 180% 25sec

Efficiency – AC – AC

%

90% at full load and rated input voltage

Efficiency – Inverter/Converter

%

92% at full load

Output Transformer

Standard Double wound for galvanic isolation

Output Protection

Electronic and Fuse

Input Parameters
 

Rectifier Type

6 Pulse microprocessor controlled silicon rectifier

 

Input Voltage to Rectifier

VAC

380/400/415 (400V standard) 3PH 4W + Neutral

Input Voltage to Bypass

VAC

380/400/415 (400V standard) 3PH 4W + Neutral+/-10%

Input Voltage to Range Rectifier

VAC

352 to 477

Input Frequency

Hz

50

 

Input Frequency Range for Rectifier

Hz

40 to 65

Input Current THD at nominal Voltage

%

<30% at full load standard

Input Power Factor at nominal Voltage

>0.7 at full load

Battery

Battery Type

VRLA (Valve Regulated Lead Acid) or Wet

Nominal Battery Bus

VDC

360 (Float 405V) User Adjustable

AC ripple current in Float mode

%

<5 % of C10 Ahr rating of battery

DC ripple voltage in Float mode

%

<1

End of Discharge

User Adjustable via laptop

Static Bypass

Type

Thyristor Bridge

Rated Current

1.5 In

Maintenance Bypass

Standard

Overload Capacity

200% 1Min 1000% 10ms

Physical Parameters

Dimensions UPS (WxDXH)

mm

560 X 780 X 1170

660 X 800 X 1370

Weight UPS

kg

235 295 325 350 281 314

374

Colour

Anthracite Grey – RAL7016

Protection

IP21

Standards

IEC 62040-3, IEC60146-1-1, IEC 61000-4-2, EN 50091

Environmental
Operating Temperature

0-40 deg Celsius, 15 to 25 degrees recommended, 0 to 35 deg continuous

Humidity

0-90% non-condensing

Maximum Altitude

0-2000 meters without de-rating

While every precaution has been taken to ensure accuracy of this specification, Durapower Manufacturing assumes no responsibility and disclaims all liability for damages resulting from use of this information. Specification subject to without notice

These single phase units are built in a tower configuration, and are available in 3KVA and 5KVA, housing internal batteries.

External battery cabinets are available for extended run times, as well as customized constructions in additional voltage configurations, are available on request.